Shenzhen Xiangming Electronics Co., Ltd


Direct Line:+86-180-3342-5320

Skype: +8618033425320

Email: sales@sanmpower.com

product details
Home > Product > Industrial Power > PMC-24V600W1BA

Delta PMF-24V320WCGB 24V(21.6-26.4Vdc) 320W



Highlights & Features


  • Universal AC input range
  • High PF > 0.99 @ 115Vac
  • Power Boost of 200% (1200W) for 5 seconds
  • Meet Surge Immunity IEC 61000-4-5, Level 4(CM: 4kV, DM: 2kV)
  • Built-in fan speed control and fan lock protection
  • Wide operating temperature range -20°C to 70°C
parameter


Output Characteristics:

1.Nominal Output Voltage

24V

2.Output Voltage Adjustment Range

21.6-26.4Vdc

3.Output Current

25.0A (continuously operating at 24V)50.0A (Power Boost for 5 seconds at 24V)

4.Output Power

600W

5.Rise Time

<50ms typ. @ 115Vac & 230Vac (100% load)

6.Start-up Time

<800ms typ. @ 115Vac & 230Vac (100% load )

7.Hold-up Time

>20ms typ. @ 115Vac & 230Vac (100% load)

8.Ripple and noise

< 180mVpp @ 0°C to 50°C, < 240mVpp @ -20°C to 0°C

9.Line Regulation

< 0.4% typ. (@ 115 & 240Vac input, 100% load)

10.Load Regulation

< 0.625% typ. (@115 & 240Vac input, 100% load)

Input Characteristics:

1.Input Voltage Range

AC:85-264Vac DC:120-370Vdc (Refer to the Output De-rating VS. InputVoltage graph)

2.Nominal Input Frequency

47-63Hz

3.Power factor

0.99typ.@115Vac,0.94typ.@230Vac

4.Input Current

<6.50A @ 115Vac, < 3.20A @ 230Vac

5.Max Inrush Current

< 20A @ 115Vac, < 40A @ 230Vac

6.Leakage Current

< 1.5mA

7.Efficiency

> 86.0% @ 115Vac, > 89.0% @ 230Vac

Protection Characteristics:

1.Overload / Overcurrent

> 180% of rated load @ V in 115Vac, Hicc-up Mode,Non-Latching (Auto-Recovery)

2.Overvoltage

27.6-33.6V, SELV Output, Latch-off Mode

3.Over Temperature

Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)

4.Short Circuit

Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)

Environmental Characteristics:

1.Operating temperature

-20°C to +70°C

2.Storage

-25°C to +85°C

3.Operating Humidity

20 to 95% RH (no condensation)

4.Storage Humidity

20 to 95% RH (no condensation)

5.Electrical Safety

TUV UL/Cul/CB/CCC

6.Galvanic Isolation

Input-Out3KVAC(10mA),Output-Ground1.5KVAC10mA),Output-Ground500VAC10mA)1 minute

7.Harmonics

IEC/EN 61000-3-2, Class A

8.Lighting Surge:

Refer to IEC1000-4-5 Line to Line:±4KV Line to Earth: ±2KV

9.EMI

CISPR 32, EN 55032, CISPR 11, EN 55011, FCC Title 47, VCCI*: Class B

Others

1.MTBF

> 300,000 hrs. as per Telcordia SR-332

2.Cooling

DC Fan

3. Weight

1.6Kg

4.Dimension

215 x 120 x 61 mm