product details
Home > Product > LED Screen Power > PMR-5V320WDA

Delta PMR-5V320WDA  5.0V(4.5V~5.5V) 60A


Highlight & Features


  • Universal AC input voltage
  • Full corrosion resistant aluminium case and chassis
  • Built-in active PFC and conforms to harmonic current IEC/EN 61000-3-2, Class A and Class D
  • Built-in DC OK relay contact and redundancy operation (PMR-5V320WDBA and PMR-5V320WDCA)
  • Dimensions (L x W x D) : 215 x 115 x 30 mm (8.46" x 4.53" x 1.18")
  • Unit Weight : 0.86 kg (1.90 lb)
parameter


Output Characteristics:

1.Nominal Output Voltage

5V

2.Output Voltage Adjustment Range

4.50-5.50V Adjustable by VR no load condition

3.Output Current

0~60A

4.Output Power

300W

5.Efficiency(typ)

86.0% typ. @ 115Vac, 88.0% typ. @ 230Vac

6.Start-up Time

1500ms typ. @ 230Vac (100% load )

7.Hold-up Time

8ms typ. @ 115Vac & 230Vac

8.Ripple and noise

< 150mVpp @ 25 < 300mVpp @ -20

9.Line Regulation

± 0.5% typ. (@ 115Vac & 230Vac 100%load)

10.Load Regulation

± 1.0% typ.@ 115Vac & 230Vac, 0-100% load

Input Characteristics:

1.Input Voltage Range

88-264VAC

2.Nominal Input Frequency

47-63Hz

3.Power factor

0.98typ.@115Vac,0.95typ.@230Vac

4.Input Current

5.0V< 5.00A @ 115Vac, < 2.50A @ 230Vac

5.Max Inrush Current

< 20A @ 115Vac, < 40A @ 230Vac

6.Leakage Current

< 1mA @ 240Vac

Protection Characteristics:

1.Overload / Overcurrent

105-150%, Hiccup Mode, Non-Latching (Auto-Recovery)

2.Overvoltage

When output is 5.0V: 5.75-6.50V, Hiccup Mode, Non-Latching(Auto-Recovery)

3.Over Temperature

Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)

4.Short Circuit

Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)

Environmental Characteristics:

1.Operating temperature

-20° C to +70° C (Cold start at -40° C)

2.Storage

-40° C to +85° C

3.Operating Humidity

20 to 95% RH (no condensation)

4.Storage Humidity

10 to 95% RH (no condensation)

5.Electrical Safety

TUV UL/Cul/CSA/CB/CCC

6.Galvanic Isolation

Input-Out3KVAC(10mA),Output-Ground2.0KVAC10mA),Output-Ground500VAC10mA)1 minute

7.Harmonics

IEC/EN 61000-3-2, Class A and Class D

8.Lighting Surge:

Refer to IEC1000-4-5 Line to Line:±1KV Line to Earth: ±2KV

9.EMI

CISPR 22, EN 55022, FCC Title 47: Class B

Others

1.MTBF

> 700,000 hrs. as per Telcordia SR-332 I/P: 100Vac, O/P: 100% load, Ta: 35° C

2.Cooling

Convection

3. Weight

0.86Kg

4.Dimension

215*115*30(L*W*H)mm


Output De-rating VS Input Voltage:



Output De-rating VS Environment temperature:




Mechanical Drawing: