Shenzhen Xiangming Electronics Co., Ltd


Direct Line:+86-180-3342-5320

Skype: +8618033425320

Email: sales@sanmpower.com

product details
Home > Product > LED Screen Power > PMT-5V350W1AM

Delta PMT-5V350W1AM  5.0V(4.5V~5.5V) 60A NO PFC


Highlight & Features


  • AC input range selectable by switch
  • Full Aluminium casing for light weight and corrosion resistant handling
  • Built-in automatic fan speed control circuit
  • Wide operating temperature range from -20°C to +70°C and Cold start at -40°C
  • MTBF > 700,000 hrs. as per Telcordia SR-332
  • Short Circuit / Overvoltage / Overload Protections
parameter

Output Characteristics:

1.Nominal Output Voltage

5V

2.Output Voltage Adjustment Range

4.55.5V Adjustable by VR no load condition

3.Output Current

0~60A

4.Output Power

300W

5.Rise Time

< 50ms @ nominal input (100% load)

6.Start-up Time

< 1000ms @ nominal input (100% load )

7.Hold-up Time

> 16ms @ 115Vac, > 20ms @ 230Vac

8.Ripple and noise

< 150mVpp

9.Line Regulation

±0.5%

10.Load Regulation

±2.5%

Input Characteristics:

1.Input Voltage Range

90-132Vac, 180-264Vac(Selectable by Switch)

2.Nominal Input Frequency

4763HZ

3.Power factor

≥0.6

4.Input Current

< 7.00A@115Vac, < 4.00A @ 230Vac

5.Max Inrush Current

< 40A @ 115Vac, < 60A @ 230Vac

6.Leakage Current

< 3.5mA @ 240Vac

7.Efficiency(typ)

> 76.0% @ 230Vac

Protection Characteristics:

1.Overload / Overcurrent

105-150%, Hiccup Mode, Non-Latching (Auto-Recovery)

2.Overvoltage

< 5.75~7.50V, SELV Output, Latch Mode

3.Over Temperature

Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)

4.Short Circuit

Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)

Environmental Characteristics:

1.Operating temperature

-20° C to +70° C (-40° C Cold Start)

2.Storage

-40° C to +85° C

3.Operating Humidity

5-95%RHno condensation

4.Storage Humidity

10-95%RHno condensation

5.Electrical Safety

UL/cUL recognized to UL60950-1 and CSA C22.2 No.
60950-1, CB scheme to IEC60950-1

6.Galvanic Isolation

input-output3KVAC(10mA),input-FG1.5KVAC10mA),output-FG500VAC10mA)1 minute

7.Harmonics

N/A

8.Lighting Surge:

Refer to IEC1000-4-5 Line to Line:±1KV Line to Earth: ±2KV

9.EMI

CISPR 22, EN 55022, FCC Title 47: Class A (With Delta EMI filter P/N: 10DKAW5)

Others

1.MTBF

> 700,000 hrs. as per Telcordia SR-332 I/P: 100Vac, O/P: 100% load, Ta: 35° C

2.Cooling

DC Fan

3. Weight

0.81KG

4.Dimension

215*115*50(L*W*H)mm

Output De-rating VS Input Voltage:



Output De-rating VS Environment temperature:




Mechanical Drawing: