product details
Home > Product > LED Screen Power > DPS-200PB-213 A

Delta DPS-200PB-213 A 4.6V(4.14V~5.06V)  40A


Highlight & Features


  • Universal AC input voltage 90V~264V
  • Efficiency ≥ 88%(230V 50Hz/40A)
  • Full corrosion resistant aluminium chassis and conformal coating for PCB board
  • High reliability with fanless design
  • Cold start -40°C, operating -25°C~70°C
  • Low profile design for 1U installation


parameter

Output Characteristics:

1.Nominal Output Voltage

4.6V

2.Output Voltage Adjustment Range

4.145.06V Adjustable by VR no load condition

3.Output Current

0~40A

4.Output Power

200W

5.Rise time

100ms

6.Start-up Time

≤500ms

7.Hold-up Time

≥10ms

8.Ripple and noise

200mVp-p

9.Line Regulation

±0.2%typ

10.Load Regulation

±1%typ

Input Characteristics:

1.Input Voltage Range

90-264VAC

2.Nominal Input Frequency

4763HZ

3.Power factor

0.95@230V/50HZ/full load

4.Input Current

100Vac@28A load/4A(rms) Max. 240Vac@full load/2.5A(rms) Max.

5.Max Inrush Current

110Vac20A 220Vac40A

6.Leakage Current

240Vac / 50Hz1mA

7.Efficiency(typ)

230Vac/50Hz @ full load88%

Protection Characteristics:

1.Overload / Overcurrent

65A Auto recovery

2.Overvoltage

Shutdown and no damage≤7.5V Auto recovery

3.Over Temperature

Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)

4.Short Circuit

Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)

Environmental Characteristics:

1.Operating temperature

-25° C to +70° C (-40 Cold start)

2.Storage

-40° C to +85° C

3.Operating Humidity

10 to 95% RH (no condensation)

4.Storage Humidity

5 to 95% RH (no condensation)

5.Electrical Safety

CB/UL/TUV/CCC/CE/BSMI/FCC

6.Galvanic Isolation

Input-Out3KVAC(10mA),Output-Ground1.5KVAC10mA),Output-Ground500VAC10mA)1 minute

7.Harmonics

JIS C 6100032 class D EN 6100032 class D

8.Lighting Surge:

Refer to IEC61000-4-5 Line to Line:±1KV Line to Earth: ±2KV

9.EMI

a) FCC Part 15 Class B b) EN55022 Class B

Others

1.MTBF

> 700,000 hrs. as per Telcordia SR-332 I/P: 100Vac, O/P: 100% load, Ta: 35° C

2.Cooling

Convection

3. Weight

1KG

4.Dimension

210*60*30(L*W*H)mm


Output De-rating VS Input Voltage:




Output De-rating VS Environment temperature:




Mechanical Drawing:




Refer to output power de-rating curve, add less than 450mm*450mm*3mm aluminum plate auxiliary cooling: